We strive for excellence, service the customers”, hopes to become the best cooperation team and dominator enterprise for personnel, suppliers and customers, realizes value share and continuous promotion for 8 Years Exporter Afdd-32 16A Arc Fault Detection Device, To achieve reciprocal advantages, our company is widely boosting our tactics of globalization in terms of communication with overseas customers, fast delivery, the best quality and long-term cooperation.
We strive for excellence, service the customers”, hopes to become the best cooperation team and dominator enterprise for personnel, suppliers and customers, realizes value share and continuous promotion for China Arc Fault Detection Device and 16A Arc Fault Detection Device, Now, we are trying to enter new markets where we do not have a presence and developing the markets we have the already penetrated. On account of superior quality and competitive price , we will be the market leader, please don’t hesitate to contact us by phone or email, if you are interested in any of our products.
Standard | IEC/BS/EN62606,IEC/AS/NZS 61009.1 (RCBO) | ||||
Rated current | 6,10,13,16,20,25,32,40A | ||||
Rated voltage | 230/240V AC | ||||
Rated frequency | 50/60Hz | ||||
Maximum operating voltage | 1.1Un | ||||
Minimum operating voltage | 180V | ||||
Protection degree | IP20 /IP40 (Terminals/Housing) | ||||
Type & mounting arrangement | Din-Rail | ||||
Application | Consumer unit | ||||
Tripping curve | B,C | ||||
Rated residual making and breaking capacity (I△m) | 2000A | ||||
Mechanical operations | >10000 | ||||
Electrical operations | ≥1200 | ||||
Rated residual operating current (I△n) | 10,30,100,300mA | ||||
Rated short-circuit capacity (Icn) | 6kA | ||||
AFDD Test means | Automatic test function as per 8.17 IEC 62606 | ||||
Classification as per IEC 62606 | 4.1.2 – AFDD unit integrated in a protective device | ||||
Ambient operating temperature | -25°C to 40°C | ||||
AFDD ready indication | Single LED Indication | ||||
Overvoltage function | Overvoltage condition of 270Vrms to 300Vrms for 10 seconds will cause device to trip.LED indication of over-voltage trip will be provided on product re-latch. | ||||
Self test interval | 1 Hour | ||||
Earth fault current | Trip time limit (typical measured value) | ||||
0.5 x Idn | No trip | ||||
1 x Idn | <300 ms (nominally <40 ms) | ||||
5 x Idn | <40ms (nominally <40 ms)Actual Tripping Threshold |
■LED Indication:
□After tripping under a fault condition the fault status indicator will show the fault nature according to the table opposite.
□LED flashing sequence repeats every 1.5sec for next 10 sec after powering up
■Series Arc Fault:
□1 Flash – Pause – 1 Flash – Pause – 1 Flash
■Parallel Arc Fault:
□1 2 Flashes – Pause – 2 Flashes – Pause – 2 Flashes
■Over Voltage Fault:
□3 Flashes – Pause – 3 Flashes – Pause – 3 Flashes
■Self-Test Fault:
□1 Flash – Pause -1 Flash – Pause -1 Flash (At Double Rate)
We strive for excellence, service the customers”, hopes to become the best cooperation team and dominator enterprise for personnel, suppliers and customers, realizes value share and continuous promotion for 8 Years Exporter Afdd-32 16A Arc Fault Detection Device , To achieve reciprocal advantages, our company is widely boosting our tactics of globalization in terms of communication with overseas customers, fast delivery, the best quality and long-term cooperation.
8 Years Exporter China Arc Fault Detection Device and 16A Arc Fault Detection Device, Now, we are trying to enter new markets where we do not have a presence and developing the markets we have the already penetrated. On account of superior quality and competitive price , we will be the market winner, please don’t hesitate to contact us by phone or email, if you are interested in any of our products.