• nybjtp

China Factory 160A-800A 1500V Manual transfer DC switch-disconnector for solar PV system

Short Description:

Product Benefits

·Easy to install
Wiring: Switch is non-polarized, all types of wiring and connections are possible.
Easy access without tools, and auxiliary contacts can be integrated without tools.
The operating mechanism can be centered to meet the installation requirements.

·Safe reliable operation
Reliable position indicator through visible contacts.
The opening and closing of the switch is fully independent from the speed of operation, ensuring safe operation under all conditions.
High temperature withstand: no derating up to 70°C.
Ambient Temperature: -40°C to +70°C.

·Designed for harsh environments
Vibration testing (from 13.2 to 100 Hz at 0.7g).
Shock testing (15g during three cycles).
Humid temperature testing (2 cycles, 55°C/131F with 95% humidity level).
Salt mist testing(3 cycles with humidity storage, 40°C/104F, 93% humidity after each cycle).


Product Detail

Product Tags

Technical data

Rated current le 160A 250A 315A 315H 400A 630A 800A
Frame size CJD-315 CJD-630
Thermal current (lth) 160 250 315 400 400 630 800
Rated insulation voltage (Ui) 1500 1500 1500 1500 1500 1500 1500
Rated impulse withstand voltage Uimp (KV) 12 12 12 12 12 12 12
Code Number of poles Rated voltage Utilisation category Ie(A) Ie(A) Ie(A) Ie(A) Ie(A) Ie(A) Ie(A)
CJDN 2P(1P+,1P-) 4P(2P+,2P-) 1000VDC DC-PV1/DC-21B 160 250 315 400 400 630 800
CJDT 2P(1P+,1P-) 4P(2P+,2P-) 1500VDC DC-PV1/DC-21B 100 160 250 315 400 630 800
CJDT 3P(2P+,1P-) 6P(4P+,2P-) 1500VDC DC-PV1/DC-21B - - 315 400 - - -
Number of poles Rated voltage Utilisation category Ie(A) Ie(A) Ie(A) Ie(A) Ie(A) Ie(A) Ie(A)
CJDN 2P(1P+,1P-) 4P(2P+,2P-) 1000VDC DC-PV2 160 250 315 - 400 630 -
CJDT 2P(1P+,1P-) 4P(2P+,2P-) 1500VDC DC-PV2 100 160 250 - 400 630 -
CJDT 3P(2P+,1P-) 6P(4P+,2P-) 1500VDC DC-PV2 - - 315 - - - -
The short-circuit capacity is between 1000 and 1500VDC (no protection)
Rated short time withstand current lcw 1s (kAeff)   Icw 5 5 5 5 8 8 8
Rated short-circuit makingapacity lcm(kA peak)- 60 ms     Icm 10 10 10 10 10 10 10
Cable
Recommended Cu rigid cable cross section(mm) 70 120 185 185 240 2X185 2X240
Recommended Cu busbar width(mm) 20 20 20 20 25 25 25
Mechanical characteristics
Durability (number of operating cycles) 8000 8000 8000 8000 8000 8000 8000
Number of cycles of operation with current 1000 1000 1000 1000 1000 1000 1000

 