Type | Technical indicators | ||||
Output | DC voltage | 5V | 12V | 15V | 24V |
Ripple and noise | <80mV | <120mV | <120mV | <150mV | |
Voltage regulation range | ±10% | ||||
Voltage precision | ±2.0% | ±1.0% | |||
Linear adjustment rate | <±1% | ||||
Input | Start up time | 100ms、30ms、21ms:110VAC/100ms、30ms、100ms:220VAC | |||
Voltage range / frequency | 85-264VAC 47Hz-63Hz(120VDC-370VDC) | ||||
Efficiency(typical) | >78% | >81% | >83% | >87% | |
Shock current | 110VAC 20A.220VAC 40A | ||||
Protection characteristics | Overload protection | 105%-150% Type: Protection mode: burp mode automatic recovery after the abnormal condition is lifted. | |||
Short circuit protection | +VO The output abnormal condition will be restored automatically after it is removed | ||||
Environmental science | Working temperature and humidity | -10℃~+50℃;20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃;10%~95RH | ||||
Security | Pressure resistance | Input-Output:3kvac lasted for 1 minute | |||
Isolation resistance | Input-Output and Input-shell,Output-shell: 500VDC/100MΩ | ||||
Other | Size | 78x93x56mm | |||
Net weight / gross weight | 270/290g | ||||
Remarks | 1) Measurement of ripple and noise: Using a 12 “twisted-pair line with a capacitor of 0.1uF and 47uF in parallel at the terminal he measurement is carried out at 20MHz bandwidth.2)Efficiency is tested at the input voltage of 230VAC, rated load and 25℃ ambient temperature.Accuracy: including setting error, linear adiustment rate and load adjustment rate.Test method of linear adiustment rate: testing from low voltage to high voltage at rated Load adjustment rate test method: from 0%-100% rated load.The start-up time is measured in the cold start state, and the fast frequent switch machine may increase the startup time .When the altitude is above 2000 meters. the operatind temperature should be lowered by 5/1000. |
Type | DR-30 | |||
DC voltage | 5V | 12V | 15V | 24V |
Rated current | 3A | 2A | 2A | 1.5A |
Rated power | 15W | 24W | 30W | 36W |
Load regulation rate | ±1% | |||
Working current | <0.8A 110VAC <0.4A 220VAC |
Type | DR-45 | |||
DC voltage | 5V | 12V | 15V | 24V |
Rated current | 5A | 3.5A | 2.8A | 2A |
Rated power | 25W | 42W | 42W | 48W |
Load regulation rate | ±1% | |||
Working current | <1A 110VAC <0.5A 220VAC |
Type | DR-60 | |||
DC voltage | 5V | 12V | 15V | 24V |
Rated current | 6.5A | 4.5A | 4A | 2.5A |
Rated power | 32.5W | 54W | 60W | 60W |
Load regulation rate | ±1% | |||
Working current | <1.2A 110VAC <0.8A 220VAC |