We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Factory Price For CEJIA Manufacturer Direct Arc Fault Detection Device 4.5ka 6ka Afdd with MCB or RCBO Function, We now have developed a responsible name amongst many customers. Quality&customer very first are usually our constant pursuit. We spare no endeavours to help make much better solutions. Look forward to long-term cooperation and mutual advantages!
We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Surge and Protector, Abiding by our motto of “Hold well the quality and services, Customers Satisfaction”, So we provide our clients with high quality products and excellent service. Please feel free to contact us for further information.

Specification

Standard IEC/BS/EN62606,IEC/AS/NZS 61009.1 (RCBO)
Rated current 6,10,13,16,20,25,32,40A
Rated voltage 230/240V AC
Rated frequency 50/60Hz
Maximum operating voltage 1.1Un
Minimum operating voltage 180V
Protection degree IP20 /IP40 (Terminals/Housing)
Type & mounting arrangement Din-Rail
Application Consumer unit
Tripping curve B,C
Rated residual making and breaking capacity (I△m) 2000A
Mechanical operations >10000
Electrical operations ≥1200
Rated residual operating current (I△n) 10,30,100,300mA
Rated short-circuit capacity (Icn) 6kA
AFDD Test means Automatic test function as per 8.17 IEC 62606
Classification as per IEC 62606 4.1.2 – AFDD unit integrated in a protective device
Ambient operating temperature -25°C to 40°C
AFDD ready indication Single LED Indication
Overvoltage function Overvoltage condition of 270Vrms to 300Vrms for 10 seconds will cause device to trip.LED indication of over-voltage trip will be provided on product re-latch.
Self test interval 1 Hour
Earth fault current Trip time limit (typical measured value)
0.5 x Idn No trip
1 x Idn <300 ms (nominally <40 ms)
5 x Idn <40ms (nominally <40 ms)Actual Tripping Threshold

Operation and Display

■LED Indication:
□After tripping under a fault condition the fault status indicator will show the fault nature according to the table opposite.
□LED flashing sequence repeats every 1.5sec for next 10 sec after powering up

■Series Arc Fault:
□1 Flash – Pause – 1 Flash – Pause – 1 Flash

■Parallel Arc Fault:
□1 2 Flashes – Pause – 2 Flashes – Pause – 2 Flashes

■Over Voltage Fault:
□3 Flashes – Pause – 3 Flashes – Pause – 3 Flashes

■Self-Test Fault:
□1 Flash – Pause -1 Flash – Pause -1 Flash (At Double Rate)

product-description1We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Factory Price For CEJIA Manufacturer Direct Arc Fault Detection Device 4.5ka 6ka Afdd with MCB or RCBO Function, We now have developed a responsible name amongst many customers. Quality&customer very first are usually our constant pursuit. We spare no endeavours to help make much better solutions. Look forward to long-term cooperation and mutual advantages!