We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Factory Price For CEJIA Manufacturer Direct Arc Fault Detection Device 4.5ka 6ka Afdd with MCB or RCBO Function, We now have developed a responsible name amongst many customers. Quality&customer very first are usually our constant pursuit. We spare no endeavours to help make much better solutions. Look forward to long-term cooperation and mutual advantages!
We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Surge and Protector, Abiding by our motto of “Hold well the quality and services, Customers Satisfaction”, So we provide our clients with high quality products and excellent service. Please feel free to contact us for further information.
Standard | IEC/BS/EN62606,IEC/AS/NZS 61009.1 (RCBO) | ||||
Rated current | 6,10,13,16,20,25,32,40A | ||||
Rated voltage | 230/240V AC | ||||
Rated frequency | 50/60Hz | ||||
Maximum operating voltage | 1.1Un | ||||
Minimum operating voltage | 180V | ||||
Protection degree | IP20 /IP40 (Terminals/Housing) | ||||
Type & mounting arrangement | Din-Rail | ||||
Application | Consumer unit | ||||
Tripping curve | B,C | ||||
Rated residual making and breaking capacity (I△m) | 2000A | ||||
Mechanical operations | >10000 | ||||
Electrical operations | ≥1200 | ||||
Rated residual operating current (I△n) | 10,30,100,300mA | ||||
Rated short-circuit capacity (Icn) | 6kA | ||||
AFDD Test means | Automatic test function as per 8.17 IEC 62606 | ||||
Classification as per IEC 62606 | 4.1.2 – AFDD unit integrated in a protective device | ||||
Ambient operating temperature | -25°C to 40°C | ||||
AFDD ready indication | Single LED Indication | ||||
Overvoltage function | Overvoltage condition of 270Vrms to 300Vrms for 10 seconds will cause device to trip.LED indication of over-voltage trip will be provided on product re-latch. | ||||
Self test interval | 1 Hour | ||||
Earth fault current | Trip time limit (typical measured value) | ||||
0.5 x Idn | No trip | ||||
1 x Idn | <300 ms (nominally <40 ms) | ||||
5 x Idn | <40ms (nominally <40 ms)Actual Tripping Threshold |
■LED Indication:
□After tripping under a fault condition the fault status indicator will show the fault nature according to the table opposite.
□LED flashing sequence repeats every 1.5sec for next 10 sec after powering up
■Series Arc Fault:
□1 Flash – Pause – 1 Flash – Pause – 1 Flash
■Parallel Arc Fault:
□1 2 Flashes – Pause – 2 Flashes – Pause – 2 Flashes
■Over Voltage Fault:
□3 Flashes – Pause – 3 Flashes – Pause – 3 Flashes
■Self-Test Fault:
□1 Flash – Pause -1 Flash – Pause -1 Flash (At Double Rate)
We have been commitment to supply the competitive price ,excellent products and solutions high-quality, at the same time as fast delivery for Factory Price For CEJIA Manufacturer Direct Arc Fault Detection Device 4.5ka 6ka Afdd with MCB or RCBO Function, We now have developed a responsible name amongst many customers. Quality&customer very first are usually our constant pursuit. We spare no endeavours to help make much better solutions. Look forward to long-term cooperation and mutual advantages!
Factory Price For Surge and Protector, Abiding by our motto of “Hold well the quality and services, Customers Satisfaction”, So we provide our clients with high quality products and excellent service. Please feel free to contact us for further information.