Output | Type | MS-1000-12 | MS-1000-24 | MS-1000-36 | MS-1000-48 | MS-1000-70 |
DC Voltage | 12V | 24V | 36V | 48V | 70V | |
Rated Current | 83.3A | 41.7A | 27.8A | 20.8A | 14.3A | |
Current Range | 0~83.3A | 0~41.7A | 0~27.8A | 0~20.8A | 0~14.3A | |
Rated Power | 999.6W | 1000.8W | 1000.8W | 998.4W | 1000.1W | |
Ripple & Noise (max.note.2) | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | |
Voltage Adj. Range | 5-13.5V | 5-27.5V | 5-40V | 5-56V | 5-73V | |
Voltage Tolerance Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Linear Regulation Rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation Rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Setup, Rise Time | 200ms、50ms、20ms: 230VAC | |||||
Intput | Voltage Range | 180-264VAC(Selected by switch,110V or 220V) | ||||
Frequency Range | 47~63Hz | |||||
Efficiency (Typ.) | 85% | |||||
AC Current (Typ.) | 10A/230VAC | |||||
Inrushcurrent (Typ.) | 35A/115VAC 55A/230VAC | |||||
Leakage Current | <2.5mA/240VAC | |||||
Protection | Overload | Rated output power 105%-135% | ||||
Protection mode: turn off output and restore after restarting | ||||||
Environment | Working temperature and humidity | -20~+50°C; 20~90%RH,Non-condensing | ||||
Storage temperature and humidity | -20~+85°C,10~95% RH | |||||
Temperature Coefficient | ±0.03%7°C (0~50°C) | |||||
Vibration resistant | 10~500Hz, 2G10 minutes/cycle, X, Y and Z axes 60 minutes each; Installation: in compliance with IEC60068-2-6 |
Security | Safety regulations | GB 4943.1-2011 | ||||
Insulation resistance | IP-O/P, I/P-FG,O/P-FG:100M Ohms / 500VDC/25°C/70% RH | |||||
Electromagnetic compatibility emissions | GB 17625.1-2012 | |||||
Electromagnetic compatibility immunity | GB/T 9254-2008 Class A heavy industry standard | |||||
Other | MTBF | ≥364.6K hrs.MIL-HDBK-217F(25°C) | ||||
Size | 240*124*65mm (W*H*D) | |||||
Package | 1.7Kg; 10pcs/17Kg | |||||
Remarks | (1) Unless otherwise specified, All specification parameters are entered as 230VAC,Rated load test are making at 25°C enironment temperature. (2) Ripple and noise measurement methods: Use a12” twisted cable, At the same time, the terminal should be connected in parallel with 0.1uf and 47uf capacitors, Measurements are performed at 20MHZ bandwidth. (3) Accuracy: Includes setting error, Linear adjustment rate and load adjustment rate. (4) The power supply is considered to be part of the components in the system and needs to be verified for electromagnetic compatibility in conjunction with the terminal equipment. |