Normal working and installation conditions
- The altitude of the installation site generally does not exceed 2000m;
- The lower limit of the ambient air temperature is generaly not lower than -5 ℃,the upper limit is generaly not higher than+40℃, and its average value within 24 hours does not exceed+35 ℃;
- The relative humidity of the air shall not exceed 90% (at+25 ℃ ± 5 ℃ )
- The pollution level of the surrounding environment is pollution level 3;
- The installation category of the starter is installation category lll;
- The inclination between the starter and the vertical installation surface shall not exceed ± 5 °;
- Tripping level: CJRV-25 (X),CJRV-32 (X),CJRV-32H,CJRV-80:10A;
- Rated working hours: uninterrupted working hours, eight hour working hours.
Features
- Rated insulation voltage Ui (V): 690.
- Rated working voltage Ue (V): AC230/240,AC400/415,AC440,AC500, AC690.
- Rated frequency(Hz): 50/60.
- Rated current of shell frame level Inm (A): 25(CJRV-25,25X),32 (CJRV-32,32X CJRV-32H), 80 (CJRV-80).
- Rated current of the release In (A): (see Table 1).
- Setting current regulation range: (see Table 1).
- Rated ultimate short-circuit breaking capacity lcu (kA): (see Table 1).
- Rated operating short-circuit breaking capacity lcs (kA): (see Table 1).
- Rated impulse withstand voltage Uimp (V): 8000.
- Selective categories (A or B) and usage categories: A, AC-3.
- Before inserting the conductor (wire/conductive strip) into the terminal, the insulation length should be peeled off (mm): 10, 15 (CJRV-80).
- Cross section area of conductor (wire/conductive bar) mm²: 1~6, 2.5~25 (CJRV2-80).
- Maximum number of conductors (wires/conductive bars) allowed to be clamped in: 2, 1 (CJRV-80).
- Terminal fastening screw (or bolt)size: M4,M8(CJRV-80).
- Tightening torque of terminal fastening screws (N·m): 1.7, 6 (CJRV-80).
- Operation frequency (times/hour): ≤ 30,≤ 25 (CJRV-80).
Table 1
Product number |
Rated current of release In (A) |
Setting current Adjustment range(A) |
Rated ultimate short-circuit breaking capacity lcu, rated operating short-circuit breaking capacity lcs kA |
Flying arc
distance
(mm) |
AC 400/415V
AC 690V |
AC 690V |
Icu |
Ics |
Icu |
Ics |
CJRV-25(X) |
0.16 |
0.1~0.16 |
100 |
100 |
100 |
100 |
40 |
0.25 |
0.16~0.25 |
100 |
100 |
100 |
100 |
40 |
0.4 |
0.25~0.4 |
100 |
100 |
100 |
100 |
40 |
0.63 |
0.4~0.63 |
100 |
100 |
100 |
100 |
40 |
1 |
0.63~1 |
100 |
100 |
100 |
100 |
40 |
1.6 |
1~1.6 |
100 |
100 |
100 |
100 |
40 |
2.5 |
1.6~2.5 |
100 |
100 |
3 |
2.25 |
40 |
4 |
2.5~4 |
100 |
100 |
3 |
2.25 |
40 |
6.3 |
4~6.3 |
100 |
100 |
3 |
2.25 |
40 |
10 |
6~10 |
100 |
100 |
3 |
2.25 |
40 |
14 |
9~14 |
15 |
7.5 |
3 |
2.25 |
40 |
18 |
13~18 |
15 |
7.5 |
3 |
2.25 |
40 |
23 |
17~23 |
15 |
6 |
3 |
2.25 |
40 |
25 |
20~25 |
15 |
6 |
3 |
2.25 |
40 |
CJRV-32(X) |
32 |
24~32 |
10 |
5 |
3 |
2.25 |
40 |
CJRV-32H |
0.16 |
0.1~0.16 |
100 |
100 |
100 |
100 |
40 |
0.25 |
0.16~0.25 |
100 |
100 |
100 |
100 |
40 |
0.4 |
0.25~0.4 |
100 |
100 |
100 |
100 |
40 |
0.63 |
0.4~0.63 |
100 |
100 |
100 |
100 |
40 |
1 |
0.63~1 |
100 |
100 |
100 |
100 |
40 |
1.6 |
1~1.6 |
100 |
100 |
100 |
100 |
40 |
2.5 |
1.6~2.5 |
100 |
100 |
4 |
4 |
40 |
4 |
2.5~4 |
100 |
100 |
4 |
4 |
40 |
6.3 |
4~6.3 |
100 |
100 |
4 |
4 |
40 |
10 |
6~10 |
100 |
100 |
4 |
4 |
40 |
14 |
9~14 |
50 |
25 |
4 |
4 |
40 |
18 |
13~18 |
50 |
25 |
4 |
4 |
40 |
23 |
17~23 |
50 |
25 |
4 |
4 |
40 |
25 |
20~25 |
50 |
25 |
4 |
4 |
40 |
32 |
24~32 |
50 |
25 |
4 |
4 |
40 |
CJRV-80 |
25 |
20~25 |
50 |
17.5 |
4 |
2 |
50 |
32 |
23~32 |
50 |
17.5 |
4 |
2 |
50 |
40 |
30~40 |
50 |
17.5 |
4 |
2 |
50 |
50 |
37~50 |
50 |
17.5 |
4 |
2 |
50 |
65 |
48~65 |
50 |
17.5 |
4 |
2 |
50 |
80 |
63~80 |
50 |
17.5 |
4 |
2 |
50 |
![CJRV Motor circuit breaker_25【宽28.22cm×高28.22cm】](https://www.cje-group.com/uploads/CJRV-Motor-circuit-breaker_25【宽28.22cm×高28.22cm】.jpg)