It can be our responsibility to satisfy your requirements and successfully serve you. Your pleasure is our greatest reward. We’ve been searching forward for your check out for joint expansion for One of Hottest for 1P+N 6ka 16A 230V Arc Fault Circuit Interrupter (AFDD), Sincerely look ahead to serving you within the in the vicinity of foreseeable future. You happen to be sincerely welcome to go to our firm to talk small business face to face with each other and create long-term co-operation with us!
It can be our responsibility to satisfy your requirements and successfully serve you. Your pleasure is our greatest reward. We’ve been searching forward for your check out for joint expansion for China Arc Fault Circuit Interrupter and Afci, Our company is working by the operation principle of “integrity-based, cooperation created, people oriented, win-win cooperation”. We hope we can have a friendly relationship with businessman from all over the world.
Standard | IEC/BS/EN62606,IEC/AS/NZS 61009.1 (RCBO) | ||||
Rated current | 6,10,13,16,20,25,32,40A | ||||
Rated voltage | 230/240V AC | ||||
Rated frequency | 50/60Hz | ||||
Maximum operating voltage | 1.1Un | ||||
Minimum operating voltage | 180V | ||||
Protection degree | IP20 /IP40 (Terminals/Housing) | ||||
Type & mounting arrangement | Din-Rail | ||||
Application | Consumer unit | ||||
Tripping curve | B,C | ||||
Rated residual making and breaking capacity (I△m) | 2000A | ||||
Mechanical operations | >10000 | ||||
Electrical operations | ≥1200 | ||||
Rated residual operating current (I△n) | 10,30,100,300mA | ||||
Rated short-circuit capacity (Icn) | 6kA | ||||
AFDD Test means | Automatic test function as per 8.17 IEC 62606 | ||||
Classification as per IEC 62606 | 4.1.2 – AFDD unit integrated in a protective device | ||||
Ambient operating temperature | -25°C to 40°C | ||||
AFDD ready indication | Single LED Indication | ||||
Overvoltage function | Overvoltage condition of 270Vrms to 300Vrms for 10 seconds will cause device to trip.LED indication of over-voltage trip will be provided on product re-latch. | ||||
Self test interval | 1 Hour | ||||
Earth fault current | Trip time limit (typical measured value) | ||||
0.5 x Idn | No trip | ||||
1 x Idn | <300 ms (nominally <40 ms) | ||||
5 x Idn | <40ms (nominally <40 ms)Actual Tripping Threshold |
■LED Indication:
□After tripping under a fault condition the fault status indicator will show the fault nature according to the table opposite.
□LED flashing sequence repeats every 1.5sec for next 10 sec after powering up
■Series Arc Fault:
□1 Flash – Pause – 1 Flash – Pause – 1 Flash
■Parallel Arc Fault:
□1 2 Flashes – Pause – 2 Flashes – Pause – 2 Flashes
■Over Voltage Fault:
□3 Flashes – Pause – 3 Flashes – Pause – 3 Flashes
■Self-Test Fault:
□1 Flash – Pause -1 Flash – Pause -1 Flash (At Double Rate)
It can be our responsibility to satisfy your requirements and successfully serve you. Your pleasure is our greatest reward. We’ve been searching forward for your check out for joint expansion for One of Hottest for 1P+N 6ka 16A 230V Arc Fault Circuit Interrupter (AFDD), Sincerely look ahead to serving you within the in the vicinity of foreseeable future. You happen to be sincerely welcome to go to our firm to talk small business face to face with each other and create long-term co-operation with us!