• nybjtp

Wholesale Price GV2-M16 Electrical Motor protection circuit breaker

Short Description:

GV2 motor air switch is suitable for AC voltage to 690V. Current is 0.1A to 80A, as overload, phase failure, short circuit protection and infrequent start control of three-phase squirrel cage asynchronous motor. Electrical line protection and infrequent load transfer can also be used as an isolator.


Product Detail

Product Tags

Pollution Degree

The GV2 motor air switch has a pollution resistance rating of three, and can be operated in a three pollution environment as defined in the lEC947 standard (industrial environment).

 

Environmental Protection

GV2 motor air switch has fully considered environmental protection factors in the manufacturing process, and most parts are recyclable.

 

Ambient Temperature

  • GV2 motor air switch can be used at -5°C to + 40°C. Above + 40°C or below -5°C.
  • The user should negotiate with the manufacturer.

 

General Characteristics

  • GV2 series motor air switch and auxiliary equipment meet the following international standards.
  • IEC 60947.1 standard/IEC 60947.2 circuit breaker/IEC 60947.4.1
  • GV2 motor air switch has CE certification

 

Technical parameters

GV2-M20 MOTOR WITH THERMAL MAGNETIC PROTECTIVE AIR SWITCH

PUSH BUTTON CONTROL OR TRANSFER SWITCH CONTROL
50/60Hz,AC-3 standard,
three-phase motor rated power
Thermal trip setting range Magnetic trip current Ithe current with case Model(button control) Weight
230V 400V 415V 440V
KW KW KW KW A A A KG
- - - - 0.1~0.16 1.5 0.16 GV2-M2001 0.26
- - - - 0.16~0.25 2.4 0.25 GV2-M2002 0.26
- - - - 0.25~0.40 5 0.40 GV2-M2003 0.26
- - - - 0.40~0.63 8 0.63 GV2-M2004 0.26
- - - 0.37 0.63~1 13 1 GV2-M2005 0.26
- 0.37 - 0.55 1~1.6 22.5 1.6 GV2-M2006 0.26
0.37 0.75 0.75 1.1 1.6~2.5 33.5 2.5 GV2-M2007 0.26
0.75 1.5 1.5 1.5 2.5~4 51 4 GV2-M2008 0.26
1.1 2.2 2.2 3 4~6.3 78 6.3 GV2-M2010 0.26
2.2 4 4 4 6~10 138 9 GV2-M2014 0.26
3 5.5 5.5 7.5 9~14 170 13 GV2-M2016 0.26
4 7.5 9 9 13~18 223 17 GV2-M2020 0.26
5.5 11 11 11 17~23 327 21 GV2-M2021 0.26
5.5 11 11 11 20~25 327 23 GV2-M2022 0.26
7.5 15 15 15 24~32 416 24 GV2-M2032 0.26
Note: GV2-M20 is the same as GV2-ME14

 

GV2-RS32 MOTOR WITH THERMAL MAGNETIC PROTECTIVE AIR SWITCH

TRANSFER SWITCH CONTROL
50/60Hz,AC-3 standard rated power of three-phase motor Thermal trip setting range Magnetic trip current(Id±20%) Model(button control) Weight
230V 400V 415V 440V
KW KW KW KW A A A KG
- - - - 0.1~0.16 1.5 GV2-RS3201 0.26
- - - - 0.16~0.25 2.4 GV2-RS3202 0.26
- - - - 0.25-0.40 5 GV2-RS3203 0.26
- - - - 0.40~0.63 8 GV2-RS3204 0.26
- - - 0.37 0.63~1 13 GV2-RS3205 0.26
- 0.37 - 0.55 1~1.6 22.5 GV2-RS3206 0.26
0.37 0.75 0.75 1.1 1.6~2.5 33.5 GV2-RS3207 0.26
0.75 1.5 1.5 1.5 2.5~4 51 GV2-RS3208 0.26
1.1 2.2 2.2 3 4~6.3 78 GV2-RS3210 0.26
2.2 4 4 4 6~10 138 GV2-RS3214 0.26
3 5.5 5.5 7.5 9~10 170 GV2-RS3216 0.26
4 7.5 9 9 13~18 223 GV2-RS3220 0.26
5.5 11 11 11 17~23 327 GV2-RS3221 0.26
5.5 11 11 11 20~25 327 GV2-RS3222 0.26
7.5 15 15 15 24~32 416 GV2-RS3232 0.26

 

GV2-LS32 MOTOR WITH THERMAL MAGNETIC PROTECTIVE AIR SWITCH

TRANSFER SWITCH CONTROL
50/60Hz,AC-3 standard rated power of three-phase motor Protection rating Magnetic trip current(Id±20%) With JRS4-d overload relay Model(button control) Weight
230V 400V 415V 440V
KW KW KW KW A A KG
- - - - 0.4 5 JRS4-1303d GV2-LS3203 0.33
- - - - 0.63 8 JRS4-1304d GV2-LS3204 0.33
- - - 0.37 1 13 JRS4-1305d GV2-LS3205 0.33
- 0.37 - 0.55 1.6 22.5 JRS4-1306d GV2-LS3206 0.33
0.37 0.75 0.75 1.1 2.5 33.5 JRS4-1307d GV2-LS3207 0.33
0.75 1.5 1.5 1.5 4 51 JRS4-1308d GV2-LS3208 0.33
1.1 2.2 2.2 3 6.3 78 JRS4-1310d GV2-LS3210 0.33
2.2 4 4 4 10 138 JRS4-1314d GV2-LS3214 0.33
3 5.5 5.5 7.5 14 170 JRS4-1316d GV2-LS3216 0.33
4 7.5 9 9 18 223 JRS4-1321d GV2-LS3220 0.33
5.5 11 11 11 25 327 JRS4-1322d GV2-LS3222 0.33
7.5 15 15 15 32 6 JRS4-2355d DZS32-LS3232 0.33

 

GV3-ME50C MOTOR WITH THERMAL MAGNETIC PROTECTIVE AIR SWITCH

BUTTON CONTROL
50/60Hz,AC-3 standard rated power of three-phase motor Thermal trip setting range Magnetic trip current(Id±20%) Model(button control) Weight
230V 400V 415V 440V
KW KW KW KW A A KG
- 0.37 - 0.55 1~1.6 19.2 GV3-ME50C06 0.6
0.37 0.75 1.1 1.1 1.6~2.5 30 GV3-ME50C07 0.6
0.75 1.5 1.5 1.5 2.5~4 48 GV3-ME50C08 0.6
1.1 2.2 2.2 3 4~6 72 GV3-ME50C10 0.6
2.2 4 4 4 6~10 120 GV3-ME50C14 0.6
4 7.5 7.5 7.5 10~16 192 GV3-ME50C20 0.6
5.5 11 11 11 16~25 300 GV3-ME50C25 0.6
1 18.5 22 22 25~40 480 GV3-ME50C40 0.7
15 30 33 33 40~63 756 GV3-ME50C63 0.7
22 40 45 45 56~80 960 GV3-ME50C80 0.7
Note: GV3-ME50C is the same as GV3-M50C

 

 

 

 